Energy News  
Australian Overturns 15 Years Of Nano-Science Doctrine

illustration only

Melbourne - Mar 12, 2003
An Australian mathematician has thrown 15 years of accepted scientific practice out the window by discovering a design flaw in a key component of the Atomic Force Microscope. His finding will force a rethink into the design and use of an instrument that has become a cornerstone of scientific measurement and analysis.

Dr John Sader, at University of Melbourne's Department of Mathematics and Statistics, and Particulate Fluids Processing Centre, used established mechanical principles to prove that the popular V-shaped cantilever inadvertently degrades the performance of the instrument, and delivers none of its intended benefits.

Sader's research will be published in the April issue of Review of Scientific Instruments.

In atomic force microscopy, small cantilevers are used to profile surface topography and structure. Shortly after the invention of the Atomic Force Microscope (AFM), almost two decades ago, V-shaped cantilevers were introduced to minimise the effect of lateral forces on image quality, a problem faced by the original rectangular design.

Sader's research reveals that this attempt to rectify the lateral force problem was based on a false assumption.

Instead of increasing the resistance to twisting, V-shaped microcantilevers actually maximise twist and degrade the performance of the instrument.

"This finding is surprising and counterintuitive, contradicting accepted practice and manufacturing standards worldwide where the V-shaped cantilever is the standard due to its alleged advantages," says Sader.

Users of the atomic force microscope have long put up with the geometric complexity of the V-shaped microcantilever, with resulting difficulties in calibration and interpretation, to gain improved lateral performance.

Sader's calculations establish that the simple cantilever design of a straight beam proposed for the original atomic force microscope (Physical Review Letters, 1986) offers greatly improved performance over the V-shape while facilitating calibration and measurement interpretation.

This finding has the potential to revolutionise the industry by setting a single universal standard and improving the performance of the instrument, while greatly simplifying its operation.

"Although the V-shape certainly offers strength and stability in the construction industry, its misuse has had a detrimental effect in the field of nano-science," says Sader.

Atomic Force Microscopy
The Atomic Force Microscope (AFM) has been the instrument of choice for three dimensional measurements at the atomic scale, since its invention in 1986.

The all-important cantilevers are placed in light contact with a sample and moved across its surface, detecting any change in surface topography. Cantilever calibration is a fundamental issue in the use of the instrument. There are several techniques in existence. Sader has devised one of these techniques, which is used commercially and by researchers worldwide.

The AFM is ideal for studies such as cell biology, polymer materials, biomaterials, materials science, food science, colloids, surfactants and coatings. The AFM is also capable of operation in liquids, a necessity for examining cells, tissues and other biological specimens immersed in liquid.

Measurements made from AFMs have revolutionised the way scientists quantitatively observe and think about the chemical, biological and physical world.

Community
Email This Article
Comment On This Article

Related Links
University Of Melbourne
SpaceDaily
Search SpaceDaily
Subscribe To SpaceDaily Express
Nano Technology News From SpaceMart.com
Computer Chip Architecture, Technology and Manufacture



Memory Foam Mattress Review
Newsletters :: SpaceDaily :: SpaceWar :: TerraDaily :: Energy Daily
XML Feeds :: Space News :: Earth News :: War News :: Solar Energy News


Water, Water Everywhere Nano
New York (UPI) Mar 18, 2005
One of the single biggest applications of nanotechnology could be solving the global shortage of pure water, experts told UPI's Nano World.







  • Hydrogen Vehicle Won't Be Viable Soon, Study Says
  • Global Energy Research Alliance Formed
  • New Battery Could Power World's Smallest Devices
  • US to Join Negotiations on Major International Fusion Project

  • Volcanic Hazard At Yucca Mountain Greater Than Previously Thought
  • Los Alamos Lab Working On Romanian Nuke Waste Site
  • Glitch-Plagued Czech Nuclear Plant Suffers Problems, Again
  • Glitch-Plagued Czech Nuclear Reactor Suffers Another Shutdown









  • Aurora Builds Low-speed Wind Tunnel
  • Yeager To Retire From Military Flying After October Airshow
  • Boeing Signs Technology Development Agreement With JAI For Work On Sonic Cruiser
  • Boeing Sonic Cruiser Completes First Wind Tunnel Tests



  • The content herein, unless otherwise known to be public domain, are Copyright 1995-2006 - SpaceDaily.AFP and UPI Wire Stories are copyright Agence France-Presse and United Press International. ESA PortalReports are copyright European Space Agency. All NASA sourced material is public domain. Additionalcopyrights may apply in whole or part to other bona fide parties. Advertising does not imply endorsement,agreement or approval of any opinions, statements or information provided by SpaceDaily on any Web page published or hosted by SpaceDaily. Privacy Statement